performance

  • Wavelength range: 200-1025nm
  • Optical resolution: FWHM (configuration dependent) -0.1-10.0 nm
  • Signal-to-noise ratio: (full signal) Flame-S: 250:1 Flame-T: 300:1
  • Dynamic range: 1300:1 (single acquisition) 8.5×107 (system)
  • Integration time: Flame-S: 1ms-65s Flame-T: 3.8ms-10s
  • 16-bit A/D conversion, 4 in trigger mode

apply

  • Agricultural measurement and inspection
  • Laser characterization
  • Air and water quality analysis
  • Photovoltaic analysis
  • Biomedical
  • Plasma monitoring
  • LED measurement, light measurement

 

performance

  • Scan speed: 4500 scans per second at high speed (varies depending on operational configuration and system performance)
  • Optical resolution: depends on 0.8 nm (FWHM) watts / 600 lines / mm of grating and 5 μm of slits
  • Dynamic Range (F Single Scan): 5000:1
  • Signal-to-noise ratio (F single scan): 290:1
  • Integration time: 10μs-10s
  • Buffer depth: The on-board cache can accommodate up to 50,000 spectra
  • Easy connection to other devices – simultaneous operation via Gigabit Ethernet, Wi-Fi wireless,
  • SPI and USB
  • Working temperature: 0-50 °C

apply

  • Agricultural measurement and monitoring
  • chemistry
  • biomedicine
  • Air and water quality analysis
  • Food sorting and processing

 

  • 90% very high quantization rate and very low Eternalon effect
  • Signal-to-noise ratio (> 1000:1) and increases processing speed
  • TEC cooling (up to -15°C) allows the detector to have lower noise and is more conducive to low-light detection
  • And the integration time can be continuously adjusted from 8ms to 15 minutes, and the spectrum will not be distorted and deformed
  • Provides 900 reticulated wire/mm grating (#H36) with a flash wavelength of 500 nm and has a good spectral response for both 532 nm and 785 nm laser Raman
  • Thermal stability
  • Internal shutter (optional)

apply

  • Biotechnology applications
  • Medical diagnosis
  • Protein and accounting analysis
  • Polymer analysis
  • chemistry
  • Metallurgical analysis

 

  • 90% quantization rate
  • Low electronic noise
  • Optical resolution (FWHM up to -0.035nm); resolution depends on the number of reticles and slit size of the raster
  • 14 grating options, including the HC-1 composite grating covering the range of 175-1100 nm
  • Available slits are 5 μm, 10 μm, 25 μm, 50 μm, 100 μm and 200 μm
  • Detector focusing lenses enhance signal strength
  • Signal measurements can be software-programmed to control (single or continuous), GPIOs digital interface spectrometer operation

apply

Suitable for scientific experiments with low brightness and high ultraviolet sensitivity

 

  • Optical resolution: FWHM up to 0.02nm
  • Wavelength range: 200-1100 nm, the specific spectral range and resolution configuration depends on the actual grating and slit selection
  • On-board microcontroller
  • Optical platform
  • Sampling attachments

apply

  • It is suitable for laser measurement, gas absorption measurement and measurement of atomic radiation lines

  • Wavelength range: 900-2200nm/raster NIR2
  • Optical resolution: FWHM <0.25nm
  • Dynamic range: 7.5×106 (system); 10000:1 for a single acquisition
  • Signal-to-noise ratio: 10000:1 @100ms points
  • Rasters (custom): NIR2, NIR3, NIR10, NIR11, NIR12 and NIR13

apply

  • Moisture detection
  • Medical and biotechnology applications
  • High resolution laser and fiber characteristic applications, etc